
March 22, 2021
Tactical Action - In the case of hydrogen, extinguish surrounding fires and apply cooling sprays to cylinder. Consider ...
Additional Tactical action regarding Hydrogen
Control measure - Cool pressurised gas containers
Content updated approval Steering group Jan 21 Approved by Mark Hodges. - Additional information regarding hydrogen
February 08, 2021
Hazard - Explosive materials: Not involved in fire
Emergency response plans - removed following update of Operations 3rd edition July 2020
February 05, 2021
Tactical Action - Use the appropriate extinguishing method, media, techniques and equipment
Updated title
February 01, 2021
Control measure - Substance identification
Substance identification - Training spec link updated
Hazard - Combustible dust
December 07, 2020
Control measure - Identify and manage Boiling Liquid Expanding Vapour Explosion (BLEVE) situations
Crews updated to personnel to match NOG style guide
November 23, 2020
Introduction
Hyperlink to IOR fixed
July 20, 2020
Hazard - Combustible dust
July 09, 2019
Control measure - Cool pressurised gas containers: Acetylene
Duplicate tactical action removed
Control measure - Cool pressurised gas containers
Minor amendment. Duplicate tactical action removed Approved by Mark Hodges.
Control measure - Substance identification: Acetylene
Minor amendment - Hyperlink added. Approved by M Hodges
July 05, 2019
Control measure - Cordon control: Explosives
Minor amendment- Formatting update
July 01, 2019
Strategic Action - Ensure that personnel are aware of sites using cryogenic material in an industrial process
Minor amendment - Operational Crews changed to Personnel to match NOG style guide - NFCC steering group
Strategic Action - Ensure that personnel have access to advice regarding the specific hazards presented by released cryogenic materials
Minor amendment - Operational crews changed to personnel - Approved by NFCC steering group
Strategic Action - Ensure that personnel have access to subject matter experts with a thorough understanding ...
Operational crews changed to personnel. Personnel changed to subject matter experts to reflect style guide. Approved by NFCC Steering Group.
Control measure - Identify heat reactions within oxidising materials
Minor amendment - Operational crews changed to Personnel Approved by NFCC steering group
Control measure - Select appropriate firefighting media: Oxidising materials
Minor amendment. Crews changed to personnel. Approved by NFCC Steering group
Control measure - Cordon control: Oxidising materials
Crews changed to personnel to match NOG style guide
Control measure - Identify and manage Boiling Liquid Expanding Vapour Explosion (BLEVE) situations
Crews updated to personnel to match NOG style guide
Tactical Action - Consider using heavy, coarse sprays to afford protection to personnel
Crews changed to personnel to match NOG style guide
Hazard - Gases under pressure: Involved in fire (e.g. potential Boiling Liquid Expanding Vapour Explosion (BLEVE))
Content changes approved by Steering Group 07/06/2019. Changes made to highlight impact of larger quantities of gas
Control measure - Cordon control: Cylinders and pressurised gas
Wording changed to add clarity on cordon sizes for different cylinder sizes. Approved by NFCC Steering group 07/06/19
May 08, 2019
Control measure - Identify potential combustible materials in oxygen-enriched atmospheres
Control measure - Manage the release of cryogenic materials
Control measure - Recognise consequences on processes using cryogenic materials
Control measure - Identify the potential explosive effects due to the failure of a cryogenic gas container
Control measure - Personal protective equipment (PPE): Cryogenic materials
Control measure - Containment: Cryogenic materials
Control measure - Apply cooling, considering the potential for reaction with water
Control measure - Separate oxidising materials from fuel sources
Control measure - Select appropriate firefighting media: Oxidising materials
Control measure - Manage the release of flammable solids
Control measure - Cordon control: Boil-over
Control measure - Prevent heat transfer to flammable liquid
Control measure - Select appropriate firefighting media: Flammable liquids
Control measure - Containment: Flammable liquids
Control measure - Isolate sources of ignition or heat
Control measure - Select appropriate firefighting media: Flammable vapours
Control measure - Prevent firespread
Control measure - Cordon control: Ignited flammable vapours